Water Softener Regeneration Water Usage

How Much Water Will My Water Softener Use?

This is a very often asked question and does not have a simple answer. Basically, we will produce a table of the different sizes and brands of water softeners that we carry and support with the average usage posted in the table, but a few words about how we arrive at these data are in order.

The table below will show the make, model and size of softener along with the amount of water in US gallons that the softener will use during regeneration. The information on injectors, brine line flow control rates and drain line flow control rates along with cycle durations which we use to determine total gallons used, will come from the manufacturer's specification sheets or service manuals. Water pressure is assumed to be 60psi. It is important to keep in mind that these results will vary a great deal depending on water pressure and temperature. It is also noted that while the flow rate for a given cycle is based on the duration of the cycle, not all cycles actually require water flow throughout the entire cycle. For example, the Fleck 5600 refill cycle is 24 minutes. The valve is not refilling the brine tank for the entire 24 minutes. The amount of water returned to the brine tank is dependent on an adjustable cam lobe in the back of the controller. There are numerous other factors that could alter these results. This table is meant as a general comparison guide only.

Make/Model Size Gallons Per Regeneration
Fleck 2510 24,000 grain 43
Fleck 2510 32,000 grain 61
Fleck 2510 40,000 grain 79.4
Fleck 2510 48,000 grain 79.4
Fleck 2510 64,000 grain 107
Fleck 2510 80,000 grain 132.5
Fleck 2510 110,000 grain 132.5
Fleck 5600 24,000 grain 62.02
Fleck 5600 32,000 grain 74.52
Fleck 5600 40,000 grain 84.52
Fleck 5600 48,000 grain 84.52
Fleck 5600 64,000 grain 142.24
Fleck 9000 24,000 grain x 2 51
Fleck 9000 32,000 grain x 2 58
Fleck 9000 40,000 grain x 2 63.6
Fleck 9000 48,000 grain x 2 63.6
Fleck 9000 64,000 grain x 2 119.5
Fleck 9000 80,000 grain x 2 122
Fleck 9000 110,000 grain x 2 136
Autotrol 255 & 268 24,000 grain 32
Autotrol 255 & 268 32,000 grain 39.3
Autotrol 255 & 268 40,000 grain 68.82
Autotrol 255 & 268 48,000 grain 68.82
Autotrol 255 & 268 64,000 grain 78.2
Autotrol 255 & 268 80,000 grain 104.5

Cycle times and injector flow rates for the Fleck model 7000 were unavailable at the time of this writing. The injector flow rates for the Autotrol models 255 and 268 were taken from a 4 year old publication which may or may not apply to today's Logix controlled systems. The older publication (Dealer Operation, Installation manual) is all that is available from the GE Water & Process Technologies web site.

 